Pipes and Staves

Pluvial Waters

- The concrete pipes are pre-molded concrete round pieces with male-female connection. They are used in pluvial waters galleries, airports and highways drainage, sewer galleries and culverts.
- Technical characteristics, according to NBR 8890/07 and error notice of 2008:

•  Cement: any kind of cement, in agreement with either NBR 5732 or NBR 5733 or NBR 5735 or NBR 5736 or NBR 5737;
•  Armor: it can be used either steel bars or soldered plates, in agreement with NBR 7480 or NBR 7481;
•  Steel fibers: those which follow NBR 15530 specifications;
•  Aggregates: selected, free of impurity, in agreement with NBR 7211;

- Coming next, commonly commercialized resistances and diameters classes:
Simple pipes, not armed, which are nominated: PS1 or PS2
DN
Pluvial Water
Minimum Load of Rupture kN/m
Class
PS1
PS2
200
16
24
300
16
24
400
16
24
500
20
30
600
24
36

Armed pipes, which are nominated: PA1, PA2, PA3 or PA4

Armed pipes and/or reinforced with fiber steel pipes diametric compression

DN


Minimum load of fissure (armed pipes) or free of damage load (reinforced pipes with fibers) kN/m


Mininum load of rupture kN/m
Class
PA1
PA2
PA3
PA4
PA1
PA2
PA3
PA4
300
12
18
27
36
18
27
41

54

400
16
24
36
48
24
36
54
72
500
20
30
45
60
30
45
68
90
600
24
36
54
72
36
54
81
108
700
28
42
63
84
42
63
95
126
800
32
48
72
96
48
72
108
144
900
36
54
81
108
54
81
122
162
1 000
40
60
90
120
60
90
135
180
1 100
44
66
99
132
66
99
149
198
1 200
48
72
108
144
72
108
162
216
1 500
60
90
135
180
90
135
203
270
1 750
70
105
158
210
105
158
237
315
2 000
80
120
180
240
120
180
270
360

Sanitary Sewagerio

- Concrete pipes are also used in the sanitary sewage systems (conducting and tubes net of sanitary sewage). They are resistant to chemical attack produced by the transportation of sanitary sewage residues and do not risk soil contamination, for they also have elastic joints, granting system containment, that means transported residues leaking is unlikely to occur.
- Coming next, commonly commercialized resistances and diameters classes:

Simple pipes, not armed, which are nominated: ES

Simple Concrete Pipes

DN

Minimum load of rupture kN/m
Class
ES
200
36
300
36
400
36
500
45
600
54

Armed pipes, which are nominated: EA2, EA3 or EA4

Concrete armed pipes - Sanitary sewage

DN


Minimum load of fissure (armed pipes) or free of damage load (reinforced pipes with fibers) kN/m


Minimum load of rupture kN/m
Class
EA2
EA3
EA4
EA2
EA3
EA4
300
18
27
36
72
41
54
400
24
26
48
36
54
72
500
30
45
60
45
68
90
600
36
54
72
54
81
108
700
42
63
84
63
95
126
800
48
72
96
72
108
144
900
54
81
108
81
122
162
1 000
60
90
120
90
135
180
1 100
66
99
132
99
149
198
1 200
72
108
144
108
162
216
1 500
90
135
180
135
203
270
1 750
105
158
210
158
237
315
2 000
120
180
240
180
270
360

Sewer staves

- Concrete sewer staves are pre-molded concrete rectangular pieces with male-female connection which are used in the pluvial drainage systems (Pluvial water galleries) of urban ways, highways and airports, open air or underground stream channeling, bridges and etc.
- Sewer staves must have their dimensions specified, varying its bottom and height on about 0,50m. As illustrated on board below:

Staves Dimensions

Width (m)

Height (m)

Width (m)

Height (m)

1,00

1,00

-

-

1,50

1,00

1,00

1,50

2,00

1,00

1,00

2,00

2,50

1,00

1,00

2,50

3,00

1,00

1,00

3,00

3,50

1,00

1,00

3,50

4,00

1,00

1,00

4,00

1,50

1,50

-

-

2,00

1,50

1,50

2,00

2,50

1,50

1,50

2,50

3,00

1,50

1,50

3,00

3,50

1,50

1,50

3,50

4,00

1,50

1,50

4,00

2,00

2,00

-

-

2,50

2,00

2,00

2,50

3,00

2,00

2,00

3,00

3,50

2,00

2,00

3,50

4,00

2,00

2,00

4,00

2,50

2,50

-

-

3,00

2,50

2,50

3,00

3,50

2,50

2,50

3,50

4,00

2,50

2,50

4,00

3,00

3,00

-

-

3,50

3,00

3,00

3,50

4,00

3,00

3,00

4,00

3,50

3,50

-

-

4,00

3,50

3,50

4,00

4,00

4,00

-

-